Transformer detection

Sep 28, 2019|

Shenzhen Shenchuang Hi-tech Electronics Co., Ltd(SChitec) is a high tech enterprise which specialized in phone accessories production and sales. Our main products include travel chargers, car chargers, USB cables, power banks and other digital products.All products are safe and reliable, with unique styles.products pass certificates like CE,FCC,ROHS,UL,PSE,C-Tick,etc,  If you are interested in, you can contact ceo@schitec.com directly.

 

Stay Charging Safely with SChitec

 

Transformer detection

 

First, the detection of the power transformer in the middle week:

A. Dial the multimeter to R×1 block, and check the on/off condition of each winding one by one according to the arrangement rules of the windings of the windings of the mid-week transformer, and then judge whether it is normal.

B. Detecting insulation performance: Place the multimeter in R×10k block and do the following status tests:

(1) a resistance value between the primary winding and the secondary winding;

(2) the resistance value between the primary winding and the outer casing;

(3) The resistance value between the secondary winding and the outer casing.

The above test results are divided into three cases:

(1) The resistance is infinite: normal;

(2) The resistance is zero: there is a short circuit fault;

(3) The resistance is less than infinity, but greater than zero: there is a leakage fault.

 


Send Inquiry