Opticalcoupler equipment product testing
Nov 15, 2019|
Stay Charging Safely with Schitec
product testing
1. Use the multimeter to judge whether it is good or bad, disconnect the input power supply, measure the resistance of 1 and 2 feet with R×1k file, the forward resistance is several hundred ohms, the reverse resistance is several tens of kilo ohms, and the resistance between 3 and 4 feet should be Unlimited. 1, 2 feet and any of the 3, 4 feet, the resistance is infinite, after the input is connected to the power supply, the resistance of the 3 and 4 feet is very small. Adjusting the RP, 3, 4 foot resistance changes, indicating that the device is good. Note: R × 10k file cannot be used, otherwise the launch tube will break down. 2, simple test circuit, when the power is turned on, the LED does not emit light, press SB, the LED will emit light, adjust the RP, LED luminous intensity will change, indicating that the measured opticalcoupler equipment is good.
Application
Due to the wide variety of opticalcoupler equipments, unique structure and outstanding advantages, it is widely used, mainly in the following applications:
(1) Application on logic circuits
(2) as a solid switch application
(3) Application on the trigger circuit
(4) Application in pulse amplifier circuit
The opticalcoupler equipment is applied to a digital circuit that amplifies the pulse signal.
(5) Application on linear circuits
(6) Application for special occasions