Inspection of ordinary Darlington
Nov 05, 2019| Stay Charging Safely with SChitec
Inspection of ordinary Darlington
The inside of a conventional Darlington tube is composed of a collector of two or more transistors connected together, and a plurality of emitter junctions are included between the base b and the emitter e. The multimeter can be measured using the R x 1 kΩ or R × 10 kΩ file of the multimeter.
Measure the positive and negative resistance values between the electrodes of the Darlington tube. Normally, the forward resistance value between the collector c and the base b (when the NPN tube is measured, the black meter is connected to the base b; when the PNP tube is measured, the black meter is connected to the collector c) and the common silicon transistor is electrically connected. The forward resistance values are similar, ranging from 3 to 10 kΩ, and the reverse resistance value is infinite. The forward resistance between the emitter e and the base b (the black meter is connected to the base b when measuring the NPN tube; the black meter is connected to the emitter e when the PNP tube is measured) is between the collector c and the base b The forward resistance value is 2 to 3 times, and the reverse resistance value is infinite. The forward and reverse resistance values between the collector c and the emitter e should be close to infinity. If the positive and negative resistance values between the c and e poles of the Darlington tube or the positive and negative resistance values between the b and e poles, b and c poles are close to 0, the tube has been broken down. damage. If the positive and negative resistance values between the b and e poles of the Darlington tube are measured to be infinite, the tube is open circuit damaged.